ASSEMBLY
Table-Top Models (3, 6 & 12 gallon)
Base Mounting Diagram
Table-top models (3, 6 & 12 gallon - single and twin)
must be positioned on a firm, level stand, or existing
counter top, and bolted in place. These models are
supplied with four threaded mounting bushings
welded to the underside of the base. An optional
support stand with level adjustable legs is available.
Once the kettle is secure, screw tilt handle into the
threaded hole provided at the right side of kettle.
Floor Type Leg Mount Models (20 gallon)
Base Mounting Diagram
Position on a firm, level surface, and bolt two
flange feet in place. Once the kettle is secure,
screw tilt handle into the threaded hole provided
at the right of kettle.
ELECTRICAL
ENSURE THE ELECTRICAL SUPPLY MATCHES
THE KETTLE'S REQUIREMENTS AS STATED
ON THE RATING LABEL.
This kettle is built to comply with applicable
standards of manufacturers. Included among
these approval agencies are UL, NSF, ASME/Ntl.
Bd., CSA, ETL, and others. Many local codes
exist, and it is the responsibility of the owner and
installer to comply with these codes.
The electrical supply must match the power
requirements specified on the kettle’s rating plate.
The copper wiring must be adequate to carry the
required current at the rated voltage. Refer to the
Specification Sheet for all electrical specifications.
Note: Maximum voltage for LVD (low volt
directive for Europe) to be 440 volts for CE
marked appliances.
WIRE CONNECTION
If unit does not have cord and plug option, remove
the screw at the rear of the console cover and
remove the cover. A wiring diagram is affixed to
the underside of the cover. Feed permanent
copper wiring through the cut-out in the rear or
bottom of the console, and fasten to the three
connection terminal block, which is mounted on
the top of the console’s control panel. Be sure to
connect the ground wire to the separate ground
terminal connector (ground lug). Replace console
cover and secure it with the screw.
The kettle is wired for 3-phase operation at the
factory. For single phase operation, rewire the
terminal block to that shown in the above diagram.
RED
YELLOW
BLACK
BLACK
BLUE
RED
L1 L2 L3
THREE
PHASE
RED
YELLOW
BLACK
BLACK
BLUE
RED
L1 L2
SINGLE
PHASE
28 1/2" 2 1/4"
14.5"
32"
12"
1 1/4"
1 1/4"
1 1/4"
KET-20-T
Model # A B C
TKET-3-T 18" 2 1/4" 1 1/4"
TKET-6-T 24" 5 5/8" 4 7/8"
TKET-12-T 30" 7 7/8"
7 3/4"
14 1/2" 1 1/4"
12.5"
12.5"
18"
10"
10"
1 1/4"
1 1/4"
1 1/4"
1 1/4"
A
BC
1.25 "
KET-3-T
KET-6-T
KET-12-T
TKET-3-T
TKET-6-T
TKET-12-T
5/16" - 18
threaded
bushings