Cleveland 24-CGA-10 Specifications Page 67

  • Download
  • Add to my manuals
  • Print
  • Page
    / 120
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 66
Replace the
on/off rocker
switch
Yes
Connect power
to steamer.
No
Is the red light on?
Is there power to
the steamer?
Is there water in
the sight glass?
Yes
See
Steamer won't
fill.
No
Has the steam
generator ignited?
Yes
No
Does the steamer
steam in manual
mode?
Yes
Replace
the timer
Yes
Is there power to
the Timed/Manual
switch?
No
Repair or
replace the
wiring to the
switch
Is there power
from the Timed/
Manual switch?
Yes
Replace the
switch
No
Does the steamer
have the optional
door switch?
Yes
Replace the
door switch
Is there 120 VAC
accross the coil of
the steam
solenoid.?
No
PROBLEM:
24CGA10
Steam
cabinet won't
steam with time on
the timer and time/
manual switch in
the timed position
Yes
No
See
Steamer
generator
won't ignite
No
Steam cabinet
won't steam
Does the steam
cabinet steam
when the door
switch is
bypassed?
Yes
Yes
No
Replace the
steam solenoid
Repair
or replace the
wiring to the steam
solenoid
No
Page view 66