Cleveland MKET-20-T User Manual Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
WIRING DIAGRAM
D/ Problem: Red LED remains illuminated even though water has been added.
Possible Causes
1. Defective low water level probe.
2. Defective control box.
Fault Isolation Procedure
Step
Test Result Remedy
1. Yes Replace or clean defective low water level
probe.
Remove wire from low water level probe
and ground the wire to the body of the
kettle. Does the red LED turn off?
No Spray contact cleaner-on-control box
terminals and edge connector. Try box
again. If problem still exists, replace
defective control box.
ELECTRIC NOTE: DUAL VOLTAGE OF 200/380 SHOWN ON CHART REQUIRE A THREE WIRE
SINGLE PHASE OR POUR WIRE THREE PHASE ELECTRICAL SUPPLY.
ELECTRICAL SUPPLY . STANDARD WATTAGE HIGH WATTAGE
208V 240V 220/380V 480V 208V 240V 220/380V
GALS
LITERS
kW A
1PH
A
3PH
kW A
1PH
A
3PH
kW A
3PH
KW A
1PH
A
3PH
kW A
3PH
kW A
3PH
KW A
3PH
12 34 11.0 54.9 34.9 14.2 62.1 39.1
11.5 19.8 14.3 29.2
17.7
13.5
41.8
17.6
97.0
14.2
24.0
20 80 13.5 66.7 41.8 17.6 75.7 47.0
14.2 24.0 14.3 29.2
17.7
16.0
48.6
20.8
54.9
17.0
28.1
Page view 12
1 2 ... 8 9 10 11 12 13 14 15 16