HORIZONTAL AGITATOR KETTLE
OPERATIONS AND CLEANING INSTRUCTIONS
CLEANING INSTRUCTIONS
As with all equipment that has electrical components, care must be exercised when using
water and chemicals to clean food service equipment. Use a mild detergent following
instructions of the chemical manufacturer. Do not spray water on electrical control panel
or components. Do not use harsh or caustic chemicals, especially on o-rings and gaskets.
1. Rinse out food debris from the kettle and flush through the metering filling
station (MFS or food pump) if they are still connected. If the kettle is not
connected to the food pump, open the valve and allow rinse water to flush into
the floor drain.
2. Remove agitator arm:
a. Rotate the agitator until the quick release pull pin is on the top.
b. Turn power to OFF as a safety precaution.
c. Pull pin out.
d. Slide coupling toward side of kettle.
e. Carefully lift end of agitator, pull back and lift out.
f. Remove bushing from shaft holder.
g. Remove scraper blades from agitator by using the spring removal tool
provided with the kettle.
h. Wash agitator arm, scraper blades, and springs with mild dish detergent or
in dish machine. Air dry.
3. Wash the inside of the kettle with a mild dish detergent as you would any pot
or pan. Flush liquid through MFS or by opening the valve. Rinse thoroughly.
4. Remove the valve and tee from the bottom of the kettle by removing the
clamp. Remove o-rings. Wash and dry thoroughly. When re-installing the
valve, apply USDA approved food grade grease (Chesterton 622 or equal) to
o-rings. Gently push tee and valve body in place and secure with clamps.
5. Clean outer drive shaft seal on the side of the kettle by removing thumb
screws. Slide seal retainer plate and quad ring away from the kettle or shaft
housing. Clean the shaft, seal and quad ring. Before re-installing, apply a
liberal amount of USDA approved food grade grease to the opening around
the shaft and slide quad ring back in place. Push the seal retainer place back in
place and tighten with thumb screws.
6. Remove temperature sensor probe by removing clamp. Slide sensor out of seal
holder. Remove o-rings. Clean sensor, seal and o-rings. Before re-installing,
apply a liberal amount of USDA approved food grade grease on o-rings.