Page view 2
TROUBLESHOOTING AND
MAINTENANCE PROCEDURES
The following trouble shooting guide and maintenance procedures
are meant to be used by Qualified Service Technician
For periodic maintenance recommendations see “Operators Manual”.
70°
3. When properly
adjusted,
cover should
rest at 70°.
2. Using a 7/16”
wrench adjust
left and right
bolts evenly.
1. Fully lift cover to
release spring
tension.
RECOMMENDED SPARE PARTS LIST
ITEM ON. DESCRIPTION QTY.
KE55069-7 SAFETY THERMOSTAT 1
SK50905-2 LIGHT 1
KE52936-13 FUSE, 1 AMP, 250V 1
SK2498399 SHAFT ASSEMBLY, POTENTIOMETER 1
SK2474100 SWITCH, OP/OFF, 120V 1
KE603902-7 CONTACTOR 2
SK53838-30 TRANSFORMER 1
SK2343502 SWITCH, POWER TILT 1
KE52936-9 FUSE, 15 AMP, 250 V 1
SK2345100 THERMOSTAT SENSOR 1
SK2142002 TEMPERATURE SENSOR BOARD 1
CALIBRATION
INSTRUCTIONS
IIMMPPOORRTTAANNTT
: DO NOT ATTEMPT TO
CALIBRATE THE THERMOSTAT
The electronic thermostat supplied with
this skillet has been precisely calibrated
at the factory and should not require field
calibration.
HINGE
ADJUSTMENT
INSTRUCTIONS
Page view 2