NOTE:
The owner / operator / purchaser must ensure that the Water Quality
Requirements are met. Not meeting the water quality requirements will void
the original equipment warranty.
Water Quality Requirements:
TDS . . . . . . . . . . . < 60 ppm pH Factor 7.0 – 8.5
Total Alkalinity . . . < 20 ppm Free Chlorine < 0.1 ppm
Silica . . . . . . . . . . < 13 ppm Conductivity min. 20 µS/cm (50 kOhms)
Chloride . . . . . . . . < 25 ppm
T
OP
VIEW
A
34.57"
34.30"
3
0.58"
2
.44"
20.28"
REAR VIEW
B
24.40"
LEFT
23.68"
FRONT
VIEW
29.61"
VIEW
2.40"
1.58"
4.06"
4.00"
A
22.36"
16.93"
2.40"
W
D
CS
A
5.69"
RC
A
A - FOR AUTOMATIC CLEANING SYSTEM OPTION
4.76"
11.89"
B - FOR easyToUCH CONTROL OPTION
ELECTRICAL CONNECTIONS
DRAIN CONNECTION
The 3 phase 208-240 volt units will be supplied with a 10 AWG,SOOW, 4
1 1/2" tube. Do not connect other units to this drain. Drain line must be vented.
conductor 6 foot long cord. The customer will have to provide the NEMA plug
(NEMA # 15-30P or L15-30P). Unit current rating 17.9 amps.
CONNECTION FOR CLEANING SOLUTION
(Available as an option)
The 1 phase 208-220 volt units will be supplied with a 10 AWG, SOOW, 3
conductor 6 foot long cord. The customer will have to provide the NEMA plug
CONNECTION FOR RINSE SOLUTION
(Available as an option)
(NEMA # 6-30P or L6-30P). Unit current rating 22.7 amps.
The 1 phase 240 volt units will be supplied with a 10 AWG, SOOW, 3 conductor
SERVICE CLEARANCES
6 foot long cord. The customer will have to provide the NEMA plug (NEMA # 6-
50P or L6-50P). Unit current rating 24.5 amps.
3" left, 3" right, 3" rear, allow 20" on top for service.
These units cannot be hard wired to the circuit box. They must have a NEMA
plug to be connected to a mating NEMA receptacle (customer supplied) to
AGENCY APPROVALS
comply with the U.L. and NEC electrical standards.
UL, UL - Sanitation (NSF Standards).
SHIPPING WEIGHT
COLD WATER CONNECTION
190 lbs.
One 3/4" GHT (Garden Hose Thread) connection. Use NSF approved hose.
35 PSI minimum, 60 PSI maximum.
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
SECT. IIA PAGE 60