Parts Manual Gas Floor Type Convection Steamer Series: SteamCraft Model 24CGA10 1333 East 179th Street Cleveland, Ohio 44110 Phone:
108727
104035 Hinge lower 104034 Hinge upper
107314 Bumper kit (2 bumpers) 107313 Bumper only flanged foot 06162
CLEVELAND RANGE 24CGA10 SEQUENCE OF OPERATIONS Mechanical Timer 1. To turn the unit on, depress the red on/off rocker switch. • 115 VAC is sent to
• Steam is energized and sent to the cooking compartment. • When the mechanical timer times down a buzzer will sound and the timer will open removin
• 24 VAC is sent to the R3 relay coil. • R3 is energized and the R3 contacts are closed. • 115 VAC is sent through the now closed R4 contacts to t
STEAM VALVEGNDSPGND24VMV/PVL105974 MCHIGASVALVE24VTRANSFORMERHEAT STANDBY TIMERR5 COIL2R2IGNITORR5R41R1R1R23PRESS SWITCHR4 COILCONTROL MODULEMVPVR3 CO
P105974 MREDWHT/REDWHT/YEL1PRPWHT253224GRAWHT/GRAORNBLUWHTBLKRED108995 - HIGH LIMIT RESET SWITCH106144 - IGNITION ASSY30 29 12 439091 - TERMINAL BLOCK
Replace the on/off rockerswitchYesConnect powerto steamer.NoIs the red light on?Is there power tothe steamer?Is there water inthe sight glass?YesSeeSt
Steam generatorwon't fill.Is there powerto thesteamer?YesSupply power tothe steamer.NoIs there waterto thesteamer?Supply cold waterto the steamer
Is there 120 VACbetween theterminals Heat andN on the waterlevel board withthe the low probesubmerged?Is there 120 VACbetween Heat and Nterminals on t
PROBLEM:24CGA10Electronic timer displays "PAUS" and won't count downSTARTIs steam heatingthe cookingcabinetabove 192degrees (the settem
Steamerwon'tstopsteamingPROBLEM:24CGA10Steamer won't stop steaming withdoor openIs the timed/manual switchin the timed positionwith no time
PROBLEM:24CGA10 Generator over--pressurizes (relief valvedischarges constantly)Generator over-pressurizesIs discharge fromrelief valve cold?See Proble
Descaling Procedure-SteamCraft Ultra and Gemini Series1. Turn the unit OFF and open thedoors:This will drain and rinse the generator for about3 minut