Cleveland 24-CGA-10 Owner's Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
5
CHAPTER 2 GENERAL OPERATION
A. MAIN EXTERNAL POWER SWITCH
Usually the steamers main external power switch is left ON.
If the main external power switch is OFF, turn it ON as
follows:
1. OPEN water supply valves
2. Turn ON/OFF switch to OFF (Figure 2-2)
3. TIMED/MANUAL switch and timer settings are not
important in this procedure. Control panel circuits are
not powered while ON/OFF switch is OFF
4. Refer to Figure 2-1. Use main external power switch to
turn on electric power to steamer. Steam generators will
immediately start blowdown cycles. Blowdown cycle
lasts 3 minutes.
Figure 2-2 Compartment POWER
ON/OFF Control
B. DOOR INTERLOCK SWITCH (OPTIONAL)
The steamer compartments of the SteamCraft
®
Steamer can be equipped with automatic steam cutoff
switches, which turn OFF the production of steam to a cooking compartment whenever the door to that
compartment is opened.
NOTE: Even though the continued production of steam ends as soon as a door is opened, it may take
up to a minute for residual steam in the system to clear from the steam lines and the cooking
compartment. To avoid possible injury always wait until this residual steam has cleared before reaching
into the cooking compartment.
C. POWER ON (AUTOMATIC FILL)
Use this procedure at the start of a shift to prepare the steamer for operation without starting steam
generation.
When the steamer is turned ON, the steam generator automatically fills with water.
S
teamCraf
t
DRAIN LINE
MAIN EXTERNAL
POWER SWITCH
Figure 2-1 Main External Power Switch
Page view 10