PROBLEM:
Electric
Kettle Won’t
Heat
Does red light
come on when unit
is first turned on?
Does red light go
off shortly after
unit is turned on?
Yes
Add water to
jacket of Kettle.
With the
potentiometer set
at 10, is 12 VDC at
the coil of the
relay?
No
Yes
Is 16 VAC
measured across
Pins 9 and 10 on
the controller?
No
Yes
Is 16 VAC at the
secondary side of
the transformer?
No
Replace
the on/off
switch (toggle
or rotary).
Yes
Is there supply
voltage to the
primary of the
transformer?
No
Replace the
transformer.
Yes
Supply power
to the kettle.
No
Does the relay pull
in?
Yes
Replace the
relay.
No
Is there supply
voltage to the
contactor coil?
Yes
With the high limit
temporarily
bypassed, is
supply voltage at
the contactor coil?
No
Replace the
high limit.
Yes
Replace
the wire
harness in the
trunion.
No
Does the contactor
pull in?
Yes
Replace the
contactor
No
Is there supply
voltage across
each element?
Yes
No
Is there an amp
draw across each
element?
Yes
Call
Cleveland for
instructions to
repair kettle.
No
If there
is heat from the
elements and water
in the kettle steam
will form. give the
unit a little
more time.
Yes
With a jumper
across pins 5 and
7 on the controller,
is there 12 VDC
across the coil of
the DC relay?
No
With the jumper
removed and the
probe wire
grounded at the
probe, is 12 VDC
measured across
the coil of the DC
relay?
Yes
Replace the
wire harness in
the trunion
No
Add water
Yes
Does the
potentiomer have
a resistance of
50,000 ohms on
low and 0 ohms at
high?
No
Replace the
potentiometer
No
Does the probe
have a resistance
of 100,000 ohms +
10% at room
temperature?
Yes
Replace the
controller
Yes
Replace Probe
No